Product Data Sheet
FLEX TPO PLUS T-JOINT COVER
PRODUCT DESCRIPTION
Flex TPO Plus T-Joint Covers are used to seal step-offs at splice intersections. Installation is mandatory
on all 60 mil and thicker TPO membrane systems and on 45 mil systems where step-offs have not been
properly sealed. Flex TPO T-Joint Covers are made from 60 mil non-reinforced flashing cut into a 4.5
diameter circle. Packaged in a box containing 100 covers. Available in white, tan and gray.
PHYSICAL PROPERTIES
Size: 4.5 (114 mm)
Thickness: 0.060 (1.5 mm)
Packaging: 100 per box
Weight (per box): 3.5 lbs. (1.6 kg)
Material: Non-reinforced TPO Flashing
Color: White, Gray or Tan
INSTALLATION
1. Clean splice intersection area with Flex Weathered Membrane Cleaner.
2. Use a lower temperature setting on the heat welder than compared to welding reinforced
membrane. (Typically a setting of 6 on a scale of 10 is appropriate for welding TPO T- Joint
Covers.)
3. Center the Flex TPO T-Joint Cover over the splice intersection. Begin welding at the center point
and work towards the outside. Use the edge of the roller to crease the T-Joint Cover into
membrane step-offs to achieve a proper seal.
4. Using a probe, check all splices for voids and cold-welds. Make any needed repairs.
CAUTIONS AND WARNINGS
· The Flex TPO T-Joint Cover is not intended for use to overlay fasteners and plates as this requires
the use of reinforced membrane.
· Store Flex TPO T-Joint Covers in a cool, shaded area and cover with light-colored, breathable,
waterproof tarpaulins. T-Joint Covers that have been exposed to the weather for 7 days or longer
prior to use must be prepared with Flex Weathered Membrane Cleaner before hot air welding.