Flex FLS Roof Edge User Manual

Browse online or download User Manual for Hardware Flex FLS Roof Edge. Flex FLS Roof Edge User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Flexiock FLS Roof Edge
Fully Adhered or Mechanically Attached Single-Ply Version
Warranty:
Testing:
The entire roof system is covered under one warranty and inspected after the project is complete to
assure proper installation. The system is inspected after the project is complete to assure proper
installation. This ensures protection for the most vulnerable area of the roof against failure due to
extreme wind up lift pressures.
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
® FA-SO - FA-80 in 24 ga. steel and .040" aluminum tested to design pressure of 160 Ibs./fF
® FA-50 - FA-80 in .050" and .063" aluminum tested to design pressure of 180 Ibs./fF
® FA-95 - FA-125 in 24 ga. steel and .040" aluminum tested to design pressure of 110 Ibs./fF
® FA-95 - FA-125 in .050" and .063" aluminum tested to design pressure of 140 Ibs./fF
Standard Sizes:
Sizes range to accommodate mrdtiple nailers and coverage requirements.
Product Code Face Height
Nailer Coverag<
FA-50 51/4" 1 Nailer
FA-65 6%" 2 Nailers
FA-80 8V4" 3 Nailers
FA-95 9 %"
4 Nailers
FA-110 111/4"
5 Nailers
FA-125 12 %"
6 Nailers
Available Materials: Its unique design allows for covers to be manufactured in 24 ga.steel, .040", .050" and .063"
aluminum.
Splice Plates:
Interlocking, concealed splice plate design prevents splice plate migration under the fascia panels.
This creates a more aesthetically pleasing design compared to traditional cover plates or lap joints at
the seams.
Watertight: Its non-penetrating design ehminates the need for stripping-in or heat welding that is typical of
many other roof edge designs. Watertight integrity is not compromised by improper flashing
procedures, failed adhesives or lap sealants.
Competitively Priced:
The installed cost rivals even light gauge roof edge systems fabricated locally or in a roofers shop.
Efficient Design:
The fascia is provided in 12'-0" lengths with pre-punched fastening holes in the galvanized
waterdam to ensure correct fastener placement and spacing. The raised button-hole on the vertical
face of the waterdam makes it easier to install.
Colors:
Choose among a wide range of standard colors and finishes that meet your job requirements. A 20
year Kynar 500® finish warranty is included on standard colors. Custom post-coated Kynar 500
colors are available with an included 10 year Kynar 500 finish warranty or a 20 year Kynar 500 finish
warranty is available upon request. Anodized finishes are also available, but are not warranted.
Custom Capabilities:
Radius and specially fabricated products are available to meet the unique needs of each project.
Accessories:
Factory fabricated miters, scuppers and drainage accessories provide a cleaner, more aesthetically
pleasing appearance. This eliminates the need for field fabrication, providing time and labor savings.
Also Included:
All fasteners are included and will arrive to the job site with the product.
features & benefits
44
p: 800-969-0108
1:610-916-9501
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - Flexiock FLS Roof Edge

Flexiock FLS Roof EdgeFully Adhered or Mechanically Attached Single-Ply VersionWarranty:Testing:The entire roof system is covered under one warranty a

Page 2 - Print Approval:

FLEXLOCK FLS ROOF EDGE____________________________FULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSIONFA-50 TO FA-80 ANSI/SPRI ES-1 DESIGN PRESSU

Page 3

FLEXLOCK FLS ROOF EDGEFULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSIONTYPICAL FASCIA ENDCAPS AND ENDWALL FLASHINGdetail46p: 800-969-0108f: 61

Page 4

FULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSION SCUPPERS - FACTORY WELDED CONSTRUCTIONFLEXLOCK FLS ROOF EDGE SCUPPERSp: 800-969-0108f: 610-9

Page 5 - FLEXLOCK FLS RADIUS ROOF EDGE

FLEXLOCK FLS RADIUS ROOF EDGEFULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSIONIMPORTANT!MUST INDICATE PROPER RADIUS CONDITION BY CIRCLING APPR

Comments to this Manuals

No comments