Flex ISO III Tapered Roof Insulation User Manual

Browse online or download User Manual for For Home Flex ISO III Tapered Roof Insulation. Flex ISO III Tapered Roof Insulation User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
(770) 952-1442 • ATLAS ROOFING CORPORATION • 2000 RIVEREDGE PARKWAY, SUITE 800 ATLANTA, GA 30328 www.AtlasRoofing.com
Data Sheet
Other than the aforementioned representations and descriptions, Atlas Roofing Corporation (hereafter, “Seller”) makes no other representations or warranties as to the insulation sold herein. The Seller disclaims all other warranties,
express or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. Seller does, however, have a limited warranty as to the LTTR-Value of the insulation, the terms of which are available
upon request from the Seller. Seller shall not be liable for any incidental or consequential damages including but not limited to the cost of installation, removal, repair or replacement of this product. Buyer’s remedies shall be limited
exclusively to, at Seller’s option, the repayment of the purchase price or resupply of product manufactured by Atlas in a quantity equal to that of the nonconforming product. Atlas distributors, agents, salespersons or other independent
representatives have no authority to waive or alter the above limitation of liability and remedies.
PHYSICAL PROPERTIES THERMAL DATA
PROPERTY TEST METHOD RESULTS
Dimensional Stability ASTM D2126 < 2%
Compressive Strength ASTM D1621
20 psi (140 kPa) or
25 psi (172 kPa)
Water Absorption ASTM C209 & D2842 < 1.5%, < 3.5%
Water Vapor Transmission ASTM E96 < 4.0 perm (228.8ng/(Pa•s•m
2
))
Product Density ASTM D1622 Nominal 2.0 pcf (32.04 kg/m
3
)
Flame Spread ASTM E84 (10 min.)
1
40-60
Smoke Development ASTM E84 (10 min.)
1
50 -170
Tensile Strength ASTM D1623 > 730 psf (35 kPa)
Service Temperature - -100° to + 250°F
PANEL LABEL
AVERAGE THICKNESS SLOPE
LTTR
2
RSI in mm per ft. percent
AA
4.2 0.74 0.5-1.0 12-25 1/8" 1%
A
7.0 1.24 1.0 -1.5 25-38 1/8" 1%
B
9.9 1.75 1.5-2.0 38-50 1/8" 1%
C
12.9 2.28 2.0-2.5 50-63 1/8" 1%
X
5.6 0.99 0.5-1.5 12-38 1/4" 2%
Y
11.4 2.01 1.5-2.5 38-63 1/4" 2%
Q
8.5 1.5 0.5-2.5 12-63 1/2" 4%
1
Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of 75
and smoke development 450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic
insulation when used in FM 4450 or UL 1256. Physical properties listed above are presented as typical average
values as determined by accepted ASTM test methods and are subject to normal manufacturing variation..
• ASTM C1289, Type II, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi)
• CAN/ULC-S704, Type 2, Class 3 or Type 3, Class 3
• CCMC No. 12464-L
UL Certified for Canada – Insulated Roof Deck Assemblies Construction
No. C38 and 52, Meets CAN/ULC-S126, CAN/ULC-S101 and CAN/ULC-S107
• UL Standard 1256 Classification – Construction No. 120, 123 & 292
• UL Standard 790 (ASTM E108) Roofing Systems Classification
• UL Standard 263 (ASTM E119) Fire Resistance Classification
• UL Standard 1897 Uplift Resistance
• FM Standard 4450/4470 Approved
Refer to FM Approvals
®
RoofNav for Specific System Details
• IBC Chapter 26 & NBC Sections on Foam Insulation
• California State Insulation Quality Standards and Title 25 Foam
Flammability Criteria (License #TC 1231)
• Miami-Dade County Approved
• State of Florida Product Approval (FL6796)
LTTR (long term thermal resistance) values were determined in accordance with CAN/ULC-S770-09. Test samples
were third-party selected and tested by an accredited material testing laboratory. The LTTR results were reviewed by
FM Global and certified by the PIMA Quality Mark Program.
2
RSI is the metric expression of R-value (m
2
K/W).
Tapered aCFoam
®
-III InsulaTIon
DESCRIPTION:
ADVANTAGES:
APPLICATION:
INSTALLATION:
Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to inorganic coated glass facers. Tapered ACFoam
®
-III is offered in a variety of
slopes, to achieve positive drainage as well as long-term thermal resistance (LTTR). Available in 4ft x 4ft (1220mm x 1220mm) panels with 1/8" (3mm),
1/4" (6mm) and 1/2" (12mm) per foot slope. Manufactured in accordance with ASTM C1289, Type II, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi)
and CAN/ULC-S704 Type 2, Class 3 or Type 3, Class 3.
When using Tapered ACFoam
®
-III in adhered systems, field testing has confirmed significantly more efficient use of solvent-based adhesives than
with organic faced insulations. Adhesive application rates vary by manufacturer. Check adhesive manufacturer’s recommendation for application
rates. Manufactured using CFC-, HCFC- and HFC-free foam blowing technology with zero ozone depletion potential (ODP) and virtually no (negligible)
global warming potential (GWP). Recognized by the GREENGUARD Environmental Institute as resistant or highly resistant to mold growth based on
independent testing using GREENGUARD Test Method GGTM.P040 (ASTM D6329) for microbial resistance. Tapered ACFoam
®
-III contains between
3.9% and 10.9% recycled materials by weight.
Manufactured and tested for use in new and re-roofing applications. Tapered ACFoam
®
-III is used in built-up (BUR), modified bitumen, ballasted single-
ply, mechanically attached single-ply and adhered single-ply roofing systems. These roofing systems depend on proper installation for successful
performance. Refer to FM Approvals
®
RoofNav and UL Online Certifications Directory for additional application details.
Tapered ACFoam
®
-III shall be kept dry before, during and after installation. This product will burn if exposed to an ignition source of sufcient heat and
intensity. Do not apply flame directly to Tapered ACFoam
®
-III insulation. Refer to PIMA Technical Bulletin 109: Storage and Handling Recommendations
for Polyiso Roof Insulation. Typical field fastening requirements can be obtained from membrane system manufacturer or FM Global Property Loss
Prevention Data Sheets 1-29.
Prior to installation, Atlas Roofing Corporation recommends that you consult your local building codes, contract documents, professional engineer, FM
Global, Miami-Dade County and membrane manufacturer for additional installation guidelines as well as design enhancements.
© Copyright 2014, Atlas Roofing Corporation 01/14 ATL-132267-00